2-5
COMPENSATIONCOMPENSATION
COMPENSATIONCOMPENSATION
COMPENSATION
Compensation allows you to adjust your CLI-1450 to a calibrated leak
field (see Appendix D).
Press the soft key to adjust compensation. A new set of soft keys
will appear. Use the and soft keys to increment and decre-
ment the compensation value. You can find the compensation value
in the upper right-hand portion of the screen directly below the
measurement distance. Press the soft key when you have
finished.
TipTip
TipTip
Tip
You can quickly clear out the compensation value by pressing the
SHIFT +
keys.
ImportantImportant
ImportantImportant
Important
Your CLI-1450 stores a separate compensation value for each antenna
type. The value automatically goes into effect when you select the
antenna. If you are using a calibrated leak field, be sure to make the
adjustment for each type of antenna that you want to use.
NoteNote
NoteNote
Note
Compensation is only useful when performing field strength measure-
ments. If the measurement units you have selected result in an
absolute measurement, the soft key will not be available.
SEARCHING FOR A LEAKSEARCHING FOR A LEAK
SEARCHING FOR A LEAKSEARCHING FOR A LEAK
SEARCHING FOR A LEAK
The Find and Fix mode is the ideal mode for locating leaks. The
Find and Fix mode detects and displays leakage measurements;
however, the leakage measurement is not as accurate as the Measure
mode. The leakage measurement value should only be used to locate
the source of a leak. To enter the Find and Fix mode from the
Measure mode, press the soft key.