Hold input
A TTL low switch closure causes
a universal waveform to hold at
its current position (address). The
hold function can be invoked by
an input signal to the Hold input,
remotely or via the front panel
hold key.
Input impedance: 10 kΩ.
Reference clock input/output
Set to input: Input for an exter-
nal 10 MHz reference clock.
TTL/CMOS threshold level.
Set to output: Buffered version
of the internal 10 MHz reference
clock. Outputs levels nominally
1V and 4V from 50Ω.
Set to phase lock:
Used together with SYNC OUT on
a master and TRIG IN on a slave
to phase lock multiple 39As.
Outputs
Main output
Outputs selected waveform at
programmed frequency, ampli-
tude and offset.
Output impedance: 50Ω
Sync output
Multifunction output that can
be user definable or automatical-
ly selectable for
any of the following:
Waveform sync:
Produces a square wave with
50% duty cycle at the waveform
frequency for standard wave-
forms or a pulse coincident with
the first few points of a universal
waveform.
Position markers:
May be used when generating
universal waveforms, any point(s)
on the waveform may have asso-
ciated marker bits set
high or low.
Burst done:
Produces a pulse coincident with
the last cycle of a burst.
Sequence sync:
Produces a pulse coincident with
the end of a waveform sequence.
Trigger:
Selects the current trigger signal.
Useful for synchronizing gated or
burst signals.
Phase lock out:
Used to phase lock two or more
39As. Produces a positive edge
at the 0° phase point.
Cursor/marker output
Adjustable output pulse for use
as a marker in sweep mode or to
modulate the Z-axis input of an
oscilloscope to provide a cursor
for waveform editing.
Output signal level: Adjustable
from 2V to 14V, normal or invert-
ed; adjustable width
as a cursor.
Output impedance:
Typically 600Ω.
General
Display: 20 character by 4 row
alphanumeric LCD.
Stored settings: Up to 9 com-
plete instrument setups and up
to 100 universal waveforms can
be stored in battery
backed memory.
Dimensions: 130 mm (height),
212 mm (width), 330 mm
(depth).
Weight: 4.1 kg (9 lb).
Power: 230V, 115V or 100V
nominal 50/60 Hz, adjustable
internally; operating range ±
14% of nominal; 100VA maxi-
mum.
Operating range: 5°C to 40°C,
20% to 80% RH.
Storage range: -20°C to 60°C.
Environmental:
Indoor use at altitudes to 2 km,
Pollution degree 2.
Safety:
Complies with EN61010-1.
EMC:
Complies with EN50081-1
and EN50082-1.
Ordering
information
Model 39A: 40 MS/s Universal
Waveform Generator.
39A-001: Rack Mount Kit.
WaveForm DSP2: Universal
waveform creation software.
Fluke Corporation
Po Box 9090
Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186,
5602 BD Eindhoven,
The Netherlands
For more information call:
In the U.S.A. (800) 443-5853
or Fax (425) 356-5116
In Europe/M-East/Africa +31 (040) 2 675 200
or Fax +31 (040) 2 675 222
In Canada (800) 36-7600
or Fax (905) 890-6886
From other countries +1 (425) 446-5500
or Fax +1 (425) 446-5116
Visit Us on the world wide web at:
http://www.fluke.com
© Copyright 2001 Fluke Corparation. All rights reserved. Printed in the
Netherlands 05/01. Data subject to alternation without notice.
39A Universal Waveform Generator