Wavetek 147 Spezifikationen Seite 125

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 410
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 124
Reverse Path Troubleshooting: CPD (Common Path Distortion) Analysis
101
5
Technicians need to be able to associate seemingly unconnected
symptoms. For example, someone notices a minor amount of hum in the
picture of a customer; two blocks away error rates start going up on a data
modem or DMX box. Somewhere in the area you find a connector cracked at
the housing entry which has allowed moisture entry and oxidation to occur.
Note that this can and does happen to F connectors in homes or institutions.
To solve such problems, the source of the moisture ingress needs to be
found and removed, the moisture removed and the oxidation or corrosion
removed. Its likely to be cheaper, easier and faster to remove and replace
an entire device (tap, directional coupler or amplifier) than to determine and
fix the cause of the moisture ingress. If a bad F connector is found, it is good
practice to also replace the device to which the F connector was attached. In
the case of F connectors, relocation of equipment to be out of the path of
water and/or use of higher cost F connectors with better water seals is
recommended (its silly to save 25 cents on an F connector and generate a
50 dollar trouble call). (David Devereaux-Weber, University of Wisconsin -
Madison, (djdevere@facstaff.wisc.edu))
Recommended Setup for CPD Analysis
If the test point is not band limited to the reverse spectrum (in other words,
on the low band side of a diplex filter) a low pass filter may be needed to
eliminate the possibility of instrument related intermodulation products that
mimic CPD. The susceptibility to intermod is dependent on the total number
of carriers present on the input to the instrument. The measurement
technique is similar to using a band pass filter for intermodulation tests
(composite second/third order).
See Also
½ "CSO/CTB Measurements" in Chapter 6 explains how to
make composite second/third order measurements
(page 128).
The objective is to avoid bombarding the RF input of the instrument with a
large number of relatively high level signals (typically 78 channels in a 550
MHz system), while looking for low level signals. The problem is that when
attenuation is removed to see the low level beat products more clearly, the
front end of the instrument may be overloaded with the high level signals on
the same test point, and generate beat products of its own.
You might need a low pass filter when you're connecting the instrument to a
bi-directional amplifier test pointa test point with both forward and reverse
signals present. This phenomenon may present itself when performing a
reverse noise test using the SDA-5500 transmitter. To minimize the
Seitenansicht 124
1 2 ... 120 121 122 123 124 125 126 127 128 129 130 ... 409 410

Kommentare zu diesen Handbüchern

Keine Kommentare

Wayne-Dalton 9100 manuales

Manuales del propietario y guías del usuario para Cocina Wayne-Dalton 9100.
Ofrecemos 1 manuales en pdf Wayne-Dalton 9100 para descargar gratis por tipos de documentos: Manual de usuario


Wayne dalton 9100 Manual de usuario (80 paginas)


Marca: Wayne-dalton | Categoria: Kitchen | Tamaño: 5.95 MB |

  

Tabla de contenidos

9100, 9400, AND 9600

1

Package Contents

3

Door Section Identification

4

PRE-INSTALLATION

7

Spring Removal

7

Removal continued

8

Removing the Old Door

9

Extension Spring Removal

9

Installation

11

INSTALLATION

11

Attaching Quick Install Flag

11

Angle to Vertical Track

11

Horizontal Angle

12

Attaching Fully Adjustable

12

Flagangle to Vertical Track

12

Installing Q.I. Jamb Brackets

13

Bottom Section

14

Vertical Track

14

Stacking Sections

15

Top Brackets

15

U-Bar - Asymmetrical

16

Operator Bracket

17

Top Section

18

Adjusting Top Brackets

19

TorqueMaster

20

Spring Tube

20

Center Bracket Bushing

20

Cable Drum Installation

22

Drive Gear Installation

23

End Brackets

23

Counter Installation

24

Securing Center Bracket

24

Assembly

24

Positioning Support Bracket

25

Attaching Disconnect Cables

26

Mounting Disconnect

26

Handle Bracket

26

Attaching Disconnect Handle

27

Vice Clamp

28

Locking Pliers

28

Flat Tip

28

Screwdriver

28

Winding Bolt Rotation

29

Setting Spring Tension

29

Rear Support Continued

31

Side Lock

32

DoorMaster

32

Bracket

32

7/16” Drill Bit

33

Power Drill

33

7/16" Wrench

33

Trolley Installation for

34

Standard Lift

34

OPTIONAL INSTALLATION

35

Low Headroom

35

Trolley Operator

36

MAINTENANCE

37

Cleaning

37

Painting

37

Painting Continued

38

Lifetime Limited Warranty

39

Models 9100, 9400, 9600

39

Thank you for your purchase

40

9100, 9400, Y 9600

41

ADVERTENCIA

42

Contenido del paquete

43

1 19/32”

44

VISTA LATERAL DE LA SECCIÓN

44

PRE-INSTALACIÓN

47

Remoción del resorte

47

TorqueMaster®

47

Remoción del resorte de

49

Instalación

51

INSTALACIÓN

51

Colocación de la ménsula en

51

Ménsula horizontal

52

Tambores

53

SECCIÓN INFERIOR

54

Apilamiento de las secciones

55

Soportes superiores

55

Barra en U

56

Barra en U asimétrica

56

BARRA EN U

57

Casquillo del soporte central

60

Instalación del idrive

61

Instalación del engranaje

63

Soportes de los extremos

63

Asegurado del ensamblaje del

64

Colocación del soporte de

65

Colocación de los cables de

66

Colocación de la manija de

67

Cerradura lateral

72

Soporte DoorMaster

72

MANTENIMIENTO

77

LIMPIEZA

77

Pintura continuación

78

MODELO 9100, 9400 Y 9600

79

GARANTÍA LIMITADA DE POR VIDA

79

Gracias por su compra

80





Más productos y manuales para Cocina Wayne-Dalton

Modelos Tipo de documento
IDRIVE PRO 3790-Z Manual de usuario   Wayne-Dalton IDRIVE PRO 3790-Z User Manual, 52 paginas
IDRIVE 302582 Manual de usuario   Wayne-Dalton IDRIVE 302582 User Manual, 1 paginas
342295 Manual de usuario   Wayne-Dalton 342295 User Manual, 2 paginas
8124 Manual de usuario   Wayne-Dalton 8124 User Manual, 4 paginas
THERMOSPAN 125 Manual de usuario   Wayne-Dalton THERMOSPAN 125 User Manual, 4 paginas
5150 Manual de usuario   Wayne-Dalton 5150 User Manual, 4 paginas
TORQUEMASTER 5500 Manual de usuario   Wayne-Dalton TORQUEMASTER 5500 User Manual, 2 paginas
THERMOMARK 5150 Manual de usuario   Wayne-Dalton THERMOMARK 5150 User Manual, 8 paginas
8500 Manual de usuario   Wayne-Dalton 8500 User Manual, 18 paginas
Wireless Wall Station Manual de usuario   Wayne-Dalton Wireless Wall Station User Manual, 2 paginas
3014 Manual de usuario   Wayne-Dalton 3014 User Manual, 7 paginas
TORQUE MASTER PLUS 9400 Manual de usuario   Wayne-Dalton TORQUE MASTER PLUS 9400 User Manual, 10 paginas
WAYNEMARK 8100 Manual de usuario   Wayne-Dalton WAYNEMARK 8100 User Manual, 8 paginas
9600 Manual de usuario   Wayne-Dalton 9600 User Manual, 8 paginas
9400 Manual de usuario   Wayne-Dalton 9400 User Manual, 2 paginas
TORQUEMASTER 5120 Manual de usuario   Wayne-Dalton TORQUEMASTER 5120 User Manual, 38 paginas
TORQUEMASTER 6100 Manual de usuario   Wayne-Dalton TORQUEMASTER 6100 User Manual, 36 paginas
TORQUEMASTER 3663-372 Manual de usuario   Wayne-Dalton TORQUEMASTER 3663-372 User Manual, 52 paginas