Wavetek 147 Spezifikationen Seite 218

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 410
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 217
Automatic Test: Auto Test Results
194
10
NOTE: Channel 5 will always pass the adjacent channels
test because it is not recognized as an adjacent channel
with channel 4.
Viewing Intervals
To view the measurement data from an interval, use the up and down
diamond keys to highlight the interval then press the Load File soft key.
The first screen displayed is a tabular list that includes the video and audio
carrier levels along with the Delta V/A for each channel. Use the up and
down diamond keys to scroll through the list. Indicators appear within the list
to flag out-of-limit conditions. The following table explains each indicator.
* adjacent channel limit violation
over limit violation
under limit violation
> over range measurement error
< under range measurement error
E unlocked measurement error
Use the More soft key to toggle between level, C/N, hum, and
modulation measurements.
If an error occurred, the following symbols replace the measurement
values when you're viewing the list of level, C/N, hum, and modulation
measurements:
< UNDER - under range
> OVER - over range
E ERROR - synthesizer unlocked
Use the Print soft key to print out the following report:
-------------------------------------------------------------------
Acterna Autotest REPORT
Model: SDA-5510 Serial No: 1234567 Cal Date: 01/20/00
-------------------------------------------------------------------
Operator: JOHN File: PROOF1 Interval: 1
Date: 07/20/99 Time: 15:18:09 Temp: 75 F
-------------------------------------------------------------------
Seitenansicht 217
1 2 ... 213 214 215 216 217 218 219 220 221 222 223 ... 409 410

Kommentare zu diesen Handbüchern

Keine Kommentare