Field Sweeping with the SDA-5000: Considerations for Sweep in the Field
70
4
stored response during viewing. Use the up and down diamond keys to
enable the option.
Include Audio Carriers (Transmit (OPT2) and Sweepless modes
only): This selection allows the audio carriers to be excluded, resulting
in a faster sweep. Use the up and down diamond keys to include (Yes) or
exclude (No) audio carriers.
Sweep Insertion Level (Loopback (OPT2) mode only): This is the
level transmitted for each Loopback sweep point. The value entered here
is determined by the signal level units specified in the MEASUREMENT
configuration screen (see Measurements Configuration in Chapter 2,
page 25). This level is adjustable from 20 dBmV to 50 dBmV with a
stepsize of 2; the default is 20 dBmV.
Loopback Sweep Plans (Loopback (OPT2) mode only): This
selection allows you to create and edit the Loopback Sweep Plan.
The Sweep function has four operating modes, Stealth, Transmit, Loopback,
and Sweepless. The current sweep mode is indicated in the upper right-
hand corner of the screen (see Fig. 4-10). The Stealth mode allows sweep
insertion points to be injected in vacant spectrum areas. The Loopback
mode enables you to perform a rough frequency response, gain, and loss
test on active and passive devices in the field. The Sweepless mode only
measures actual system carriers. Any system carrier can be used as a data
point, even scrambled or digital carriers. In either mode, a previously stored
response can be used as a reference to the current measurement. Sweep
references are selected in the File setup menu (see Sweep References in
Chapter 11, page 201). The Transmit mode operates the same as the Scan
mode with these exceptions: sweep telemetry is transmitted, sweep points
are injected, and sweep point levels are displayed (see Scan
Measurements in Chapter 6, page 115).
Connecting the SDA-5000 to a Test Point
This section covers signal level issues and shows you how to interface with
different network architectures.
CONSIDERATIONS FOR SWEEP IN THE FIELD