User Manual 301/302
<exp > numeric value that sets the exponent parameter
GAUSsian:EXPonent?
Response
The 302 will return the present exponent value.
EXPonential:EXPonent <exp>
Purpose
This command programs the exponent for the standard exponential waveform. This command has no affect
on arbitrary waveforms.
<exp > numeric value that sets the exponent parameter
EXPonential:EXPonent?
Response
The 302 will return the present exponent value.
DC <%_amplitude>
Purpose
This command programs the amplitude of the standard DC waveform. This command has no affect on
arbitrary waveforms.
<%_amplitude > numeric value that sets the dc level as percentage of the programmed amplitude
setting
DC?
Response
The 302 will return the present dc value.