301/302 User Manual
Output State
The main outputs can be turned on or off. The internal circuit is
disconnected from the output connector by a mechanical switch
(relay). This feature is useful for connecting the main outputs to an
analog bus. For safety reasons, when power is first applied to the
chassis, the main output is always off.
Filters
Ten filters are built into the Model 301/302, five for each channel.
These filters are available for use in various applications such as the
creation of high frequency sine waves and removing the staircase
effect from waveforms that are generated with high frequency clock
rates.
Front Panel
Indicators
There are five LEDs on the front panel. The POWER LED (Red)
illuminates at power-up and remains on until the Model 301/302 has
been turned off.
The ACCESS LED (Amber) illuminates each time a command has
been received by the Model 301/302. This light remains on during
DMA data transfer.
The REMOTE light turns on the first time the GPIB remote enable line
is true. GTL (go to local) command or power down turn this light off.
When the output state is on, the OUTPUT LED (Green) light
illuminates. There are two LEDs, one for each channel. Note that the
LEDs are part of the Main output. There is no ON indication for the
Auxiliary outputs.
Programming The
Model 301/302
The Model 301/302 has no controls on its front panel. Instrument
functions, parameters, and modes can only be accessed through
GPIB or RS232 commands. There are a number of ways to “talk” to
the instrument. They all require that an appropriate software driver be
installed in the host computer. The rest is a matter of practice and
knowledge of the language in use. There are other system
considerations like address selection that have to be settled before
programming the instrument. These topics are discussed in later
chapters.
Low level programming of the Model 301/302 is accomplished using
SCPI (Standard Commands for Programmable Instruments)
language. Programming aspects are covered in Chapters 3 and 4.
Supplied with the 301/2 is a PC software package called WaveWiz.
This provides a user interface with a familiar windows interface which
allows the user to interact with and control the 301/2 directly. Details
of how to use WaveWiz are supplied in the following pages.
Getting Started
11