User Manual 301/302
FORMat
Subsystem
The FORMat subsystem sets a data format for transferring array
information. This data format is used for commands that are
specifically designated to be affected by the FORMat subsystem.
Factory defaults after *RST are shown in bold typeface. Parameter
low and high limits are given where applicable.
Keyword Parameter Form Default,Low Limit,High Limit
:FORMat
:BORDer NORMal|SWAPped NORMal
FORMat:BORDer NORMal | SWAPped
Purpose
This command will set the byte order for the trace command.
NORMal will set low-high byte order
SWAPped will set high-low byte order
FORMat:BORDer?
Response
The 302 will return NORM, or SWAP depending on the present byte order setting.