User Manual 301/302
Internal Burst An internal timer repeatedly generates a burst of up to
1M counted output cycles. This mode is not available in
SEQ mode.
Trigger Sources
Internal Internal programmable rate generator
Period From 20 µs to 1000 s
Accuracy ±(1% + 1 µs)
External
Input Front panel BNC
Frequency 15 MHz to DC
Software IEEE 488.2 command
System Delay
Trigger to waveform output 1 Sample Clock+150 ns
STANDARD WAVEFORMS
Frequency Range Waveform dependent
Source Internal synthesizer
Sine
Frequency Range 100 µHz to 70 MHz, usable to 150 MHz
Band Flatness 5% to 10 MHz; 10%, to 37.5 MHz, 30% to 150 MHz
Programmable Parameters Start phase, 0 to 360°
Triangle
Frequency Range: 100 µHz to 5 MHz, usable above 5 MHz
Adjustable Parameters Start phase, 0 to 360°
Square
Frequency Range 100 µHz to 150 MHz
Adjustable Parameters Duty cycle, 1% to 99%
Pulse/Ramp
Frequency Range 10 mHz to 5 MHz, usable above 5 MHz
Adjustable Parameters
Delay 0% to 99.9% of period
Rise Time 0% to 99.9% of period
Specifications