User Manual 301/302
This command is a high-level command that programs the 302 to output user-defined waveform along with
its associated parameters
<seg# > selects the active segment
<sclk> numeric which sets the sample clock frequency
<ampl> numeric which sets the output amplitude
<offs> numeric which sets the output offset
APPLy:USER?
Response
The 302 will return <seg#>,<sclk>, <ampl>,<offs>
FREQuency <freq> | MINimum | MAXimum
Purpose
This command modifies the frequency of the standard waveform. It has no affect on arbitrary waveforms.
<sclk> numeric value that sets the waveform frequency
<MINimum> sets the waveform frequency to its lowest value
<MAXimum> sets the waveform frequency to its highest value
FREQuency?
Response
The 302 will return the present frequency value. The returned value will be in standard scientific format (for
example: 100mHz would be returned as 100E-3 – positive numbers are unsigned).
FREQuency:RASTer <sclk> | MINimum | MAXimum
Purpose
This command modifies the sample clock frequency of the arbitrary waveform. It has no affect on standard
waveforms.
<sclk> numeric value that sets the sample clock frequency
<MINimum> sets the sample clock frequency to its lowest value
<MAXimum> sets the sample clock frequency to its highest value
FREQuency:RASTer ?
Response
The 302 will return the present sample clock frequency value. The returned value will be in standard
scientific format (for example: 100MHz would be returned as 100E6 – positive numbers are unsigned).