301/302 User Manual
continuous operating mode. When placed in trigger, gated or burst
mode, the trigger input is made active and waits for the right condition
to trigger the instrument. In trigger and burst modes, the trigger input
is edge sensitive, i.e., it senses transitions from high to low or from
low to high to trigger the Model 301/302. The direction of the transition
is programmable. In gated mode, the trigger input is level sensitive,
i.e., the Model 301/302 is gated when the logic level is high and idle
when the level is logic low. Trigger level for this input is
programmable.
The trigger input is common to both channels. Therefore, if the model
301/302 is placed in trigger mode, both channels share the same
mode and the trigger input causes both channels to start generating
waveforms at the same time.
Phase relationship between channels is tightly controlled in trigger
mode. You should expect that both channels will start generating
waveforms with exactly the same start phase. Further control over
phase offset between channels is also provided. Applying a phase
offset between the channels is described later in this manual.
AM Input –
Channel A
The channel A AM input accepts signals that amplitude modulate the
channel A signal. The Channel A AM input becomes active only when
the AM function is selected.
AM Input –
Channel B
The channel B AM input accepts signals that amplitude modulate the
channel B signal. The Channel B AM input becomes active only when
the AM function is selected.
Sample Clock Input
The external clock input is available for those applications requiring
synchronization to one sample clock source. Normally, this input is
disabled. When enabled, the clock at this input replaces the internal
clock generator and the 301/302 generates waveforms with the
sample clock at the Sample Clock input.
Operating Modes
The 301/302 can be programmed to operate in one of four operating
modes: continuous, triggered, gated and counted burst. These modes
are described below.
As was discussed above, both channels are placed simultaneously in
triggered mode. All channels will start generating waveforms when a
valid trigger signal is received at the trigger input. Both waveforms will
start and complete at exactly the same instance.