User Manual 301/302
Selecting the SYNC
Position
The SYNC output can be programmed to output the SYNC signal at
any time referenced to the output waveform (expressed in waveform
points). This function is available in USER and SEQ modes only. Use
the following command to select the SYNC output position:
OUTPut:SYNC:POSition <value>
The SYNC position can be selected from point 0 to the last point of the
active waveform. SYNC position has to be programmed for each
segment. The default SYNC position is at the beginning of the
segment or waveform.
The query:
OUTPut:SYNC:POSition?
queries the output SYNC position and returns an integer value.
Figure 3.13 Controls for the SYNC output are on the Output tab
Generating
Arbitrary
Waveforms
The Model 301/302 cannot generate arbitrary waveforms without first
loading them into memory. A description of the arbitrary waveform
function and an explanation of how to load waveforms into memory
are given in the following paragraphs.
Configuring The Instrument