Gated Mode
The Model 301/302 can be set to operate in Gated mode only after the
INIT:CONT OFF command has been received. The output remains at
a DC level as long as the front-panel TRIG IN signal remains inactive.
The gating signal can be programmed to be either active high or
active low. As long as the proper level is present at the trigger input
connector, the Model 301/302 generates output waveforms. When the
gate signal is de-asserted, the output completes the last cycle and
resumes position at a DC level equal to the last point of the waveform.
Gated mode operates on standard waveforms, arbitrary waveforms,
and on sequences of waveforms. Observe the limitations of the gating
signal as listed in the specification section of this manual. To place the
Model 301/302 in Gated mode, use the following commands:
INIT:CONT OFF
TRIGger:GATE {OFF | ON}
The default state for the Gated mode is OFF. Turning Gated mode
ON automatically turns Burst mode off.
The query:
TRIGger:GATE?
queries the gate state and returns "0" (OFF) or "1" (ON).
In WaveWiz, select gated mode by clicking the diamond shaped
Gated button under mode on the Trigger tab. (see Figure 3.12 above).
Burst Mode
Burst mode is very similar to Triggered mode with the exception that
only one trigger signal is needed to generate a counted number of
output waveforms. In Burst mode, the output remains at a DC level as
long as the TRIG IN signal from the front panel remains inactive. The
trigger input is sensitive to either the rising edge or the falling edge.
Each time a transition at the trigger input occurs, the Model 301/302
generates the number of complete output cycles that have been
programmed in the burst count parameter. At the end of the burst, the
output resumes position at a DC level equal to the last point of the
waveform. The burst count is programmable from 1 to 1Meg. The
default burst value is 1.
Burst mode operates in standard waveforms and arbitrary waveforms
only. Note that the Model 301/302 cannot operate in Sequence and
Burst modes simultaneously. Observe the limitations of the trigger
signal as listed in the specification section of this manual. To place the
Model 301/302 in Burst mode, use the following commands:
INITitiate:CONTinuous OFF